Find out how these systems work
Mechanisms
Simon Altair IXFÌýIstanium LED®ÌýRoad luminaire, die-cast aluminium, lateral/adjustable post-top fastening.
It provides necessary public lighting with maximum energy efficiency:
Ìý
Access and maintenance via the top part, fastened with four captive screws that are invisible when installed. The electro-optic group is removable and upgradeable by means of a single piece.
Configure the Altair IXF Istanium LED Luminaire to suit you
Simon's configurator provides high quality light reducing light pollution and energy consumption
2N with regulation without control line self-regulation
The electronic equipment of the luminaire has a programmed timer that reduces the power by half after 4.5 hours from the moment of switching on.
1N without regulation
The electronic equipment delivers 100% of the power with no option to be regulated. If there is any fluctuation in the line voltage, the equipment compensates the supply current of the Istanium LED modules to maintain the luminous flux (input voltage from 208 to 277 Vac). Similarly, if the electrical cabinet has a flow regulation unit at the head, the unit will not regulate the lamp (an Istanium LED luminaire with CAD regulation is required).
IP66
Totally dustproof. Protected against strong jets of water or heavy seas.
IK09
Protection against external mechanical impact of 10 J of energy and 5 Kg/200 mm of mass and height of the hitting piece.
IK10
Protection against external mechanical impact of 20 J of energy and 5 Kg/400 mm of mass and height of the striking piece.
Body
Die-cast aluminum
Fixation System
Galvanized and painted steel sheet
Closure system
Painted die-cast aluminum lever
Diffuser
Shatterproof Flat Clear Tempered Glass
Deck
Die-cast aluminum
UNE-EN 60598-2-3
Public lighting luminaires. Part 2: corresponding to the particular type of luminaire under study.
UNE-EN 62493
Evaluation of lighting equipment in relation to human exposure to electromagnetic fields.
UNE-EN 61000-2-3
Electromagnetic compatibility (EMC). Part 3-2: Limits. Limits for harmonic current emissions (equipment with input current <= 16 A per phase).
UNE-EN 55015
Limits and methods of measurement of the characteristics related to radioelectric disturbance of lighting equipment and the like.
UNE-EN 61547
Lighting equipment for general use. Requirements relating to EMC immunity.
UNE-EN 50581
Technical documentation for the evaluation of electrical and electronic products with respect to the restriction of hazardous substances.
4.000 K
Neutral white light
3.000 K
Warm white light
2.700 K
Soft white light
XDL 2.200 K
Extra warm white light
PCA
Phosphor-Converted Amber
Protection degree IK10 - IK09 - IP66
Class
Certificates CE - ENEC
Weight 6 kg
Color temperatures NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, XDL 2.200 K, APC
Color rendering index >70
Upper hemisphere flow <1% (zonas E1)
LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC) 100.000 h
Photometric distribution (Optics) RG/ RJ/ RA/ RE/ SA/ SB/ RF/ RW