Simon Hydra

Simon Hydra

Simon Hydra Istanium LED decorative urban luminaire, in die-cast aluminium, post-top fastening.

It provides necessary public lighting with maximum energy efficiency:

 

  • Light flux > 3360 lm
  • Savings up to 65%
  • Efficiency up to 144 lm/W
  • Guaranteed thermal management
Properties
Street
Pedestrian streets
Garden park
Square
Commercial areas
Luminous Distributions

Configure the Hydra Istanium LED Luminaire to suit you

Simon's configurator provides high quality light reducing light pollution and energy consumption.

imatg_conf_hydra
Regulation

2N- with regulation without control line; self-regulation

The electronic equipment of the luminaire has a programmed timer that reduces the power by half after 4.5 hours from the moment of switching on.

 

2N+ Control line regulation

The electronic equipment has an input that is connected to the electrical cabinet. When the cabinet activates the control line voltage, the equipment delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the equipment cuts power in half.

 

CAD Head flow regulation

The luminaire's electronic equipment adapts the supply current of the Istanium LED modules proportionally to the line input voltage. The head electrical cabinet must have a device that regulates the line voltage to reduce the lighting level of the appliance. This type of regulation is ideal for taking advantage of installations with cabinet equipment already installed.

 

1N without regulation

The electronic equipment delivers 100% of the power with no option to be regulated. If there is any fluctuation in the line voltage, the equipment compensates the supply current of the Istanium LED modules to maintain the luminous flux (input voltage from 208 to 277 Vac). Similarly, if the electrical cabinet has a flow regulation unit at the head, the unit will not regulate the lamp (an Istanium LED luminaire with CAD regulation is required).

 

1-10 Regulation governed by protocol 1-10V

The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).

 

DALI regulation governed by DALI protocol

The electronic equipment delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).

Protection

IP65

Completely dustproof. Protected against water jets.

 

IP66

Completely dustproof. Protected against strong jets of water or heavy seas.

 

IK08

Protection against external mechanical shocks of 5 J of energy and 1.7 Kg/295 mm of mass and height of the impact piece.

Materials and finishes

Body

Aluminum base

 

Closure system

By stainless steel screws

 

Serpentine: GTF

Unbreakable Tempered Clear Flat Glass

 

MTT

Four-sided transparent methacrylate

 

MOT

Engraved opal methacrylate

Regulation and certification

UNE-EN 62031

LED modules for general lighting. Security requirements

UNE-EN 60598-1

luminaries. Part 1 : General requirements and tests

 

UNE-EN 60598-2-3

Public lighting luminaires. Part 2 : corresponding to the particular type of luminaire studied

 

UNE-EN 62493

Evaluation of lighting equipment with respect to human exposure to electromagnetic fields

 

UNE-EN 61000-2-3

Electromagnetic compatibility (EMC). Part 3-2 : Limits. Harmonic current emission limits (equipment with input current <= 16 A per phase).

 

UNE-EN 61000-3-3

Electromagnetic compatibility (EMC). Part 3-3 : Limits. Limitation of voltage variations, voltage fluctuations and flicker in public low voltage power supply networks for equipment with nominal current <= 16 A per phase and not subject to conditional connection.

 

UNE-EN 55015

Limitation of voltage variations, voltage fluctuations and flicker in public low voltage power supply networks for equipment with nominal current <= 16 A per phase and not subject to conditional connection.

 

UNE-EN 61547

General purpose lighting equipment. EMC immunity requirements.

 

UNE-EN 61347-2-13

Lamp control devices. Part 2-13: Particular rules for electronic control devices powered with direct current or alternating current for LED modules.

 

UNE-EN 62471:2009

Photobiological safety of lamps and devices that use lamps.

 

UNE-EN 50581

Technical documentation for the evaluation of electrical and electronic products with regard to the restriction of hazardous substances

Color Temperature

4,000K

Neutral white light

 

3,000K

Warm white light

 

2,700K

Soft white light

 

XDL 2,200K

Extra warm white light.

 

APC

Amber turned into phosphorus.

Caractéristiques techniques

Degré de protection   IK08 - IP66

Classe

Certificats   CE - ENEC

Masse   8 kg

températures de couleur  NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, APC

Índice de reproducción cromática   >70

flux de l'hémisphère supérieur   <1% (zonas E1)

Durée des voyants (L90 B10 a Ta=25 ºC y Tj=95 ºC)   100.000 h

Distribution photométrique (Optique) RG/ RJ/ RA/ RE/ SA/ RF/ RW

 
Simon Urban Solutions Catalogue
 
Simon Hydra - Technical Sheet
 
Simon Hydra - EU Declaration of Conformity