Find out how these systems work
Mechanisms
Simon Nath M Istanium LED® Road Luminaire, size M, die-cast aluminium and 5° angled lateral fixing and 0° angle post-top fastening.
Simon has various production centres, both in Spain and around the world. All are equipped with advanced technology that allows us to maintain another of our basic principles for success: performing demanding tests and controls to guarantee the quality of all our products.
The Simon Nath LED Road luminaire, size M, was designed as a solution for different road lighting applications, such as highways, roads, industrial spaces, pedestrian areas, residential areas, roundabouts and intersections, functional roads, streets and avenues, parking areas, sports facilities and large commercial warehouses.
Configure the Nath M LED Luminaire to measure according to the type of space
Simon's configurator allows you to select the technical, aesthetic and lighting characteristics of the luminaires that are most suitable for a specific space.
2N- Dimming without control line; self-dimming
The luminaire’s electronic control gear has a programmed timer that reduces the power by half 4.5 hours after it is turned on.
2N+ Dimming with control line
The electronic control gear has an input that connects it to the electrical cabinet. When the cabinet activates the voltage on the control line, the device delivers 100% of the nominal power to the Istanium LED module. When the cabinet disconnects the control line (0 volts), the device reduces the power by half.
CAD cabinet amplitude dimming
The luminaire’s electronic control gear adapts to the supply current of the Istanium LED modules, in proportion to the line input voltage. The amplitude dimming electrical cabinet must have a device that regulates the line voltage to reduce the light level of the luminaire. This dimming type is ideal to take advantage of installations with existing cabinet equipment installations.
1N without dimming
The electronic control gear delivers 100% of the power without a dimming option. If there is any fluctuation in the device’s line voltage, the supply current of the Istanium LED modules compensates to maintain the light flux (input voltage from 208 to 277 VAC). Likewise, if the electrical cabinet has a cabinet amplitude dimming device, the device will not dim the lamp (requires an Istanium LED luminaire with CAD dimming)
1-10 Dimming governed by 1-10V protocol
The electronic control gear delivers the output power to the Istanium LED modules according to the level indicated by the 1-10 signal (normally delivered by a remote management device).
DALI dimming regulated by DALI protocol
The electronic control gear delivers the output power to the Istanium LED modules according to the level indicated by the DALI signal (normally delivered by a remote management device).
IP65
Totally dustproof. Protected against water jets.
IP66
Totally dustproof. Protected against strong jets of water or heavy seas.
IK08
Protection against external mechanical impact of 5 J of energy and 1.7 Kg/295 mm of mass and height of the striking piece.
Body
Die-cast aluminum
Fixation System
Galvanized and painted steel sheet
Closure system
Painted die-cast aluminum lever
Diffuser
Shatterproof Flat Clear Tempered Glass
Deck
Die-cast aluminum
UNE-EN 62031
LED modules for general lighting. Security requirements.
UNE-EN 60598-1
luminaries. Part 1: General requirements and tests.
UNE-EN 60598-2-3
Public lighting luminaires. Part 2: corresponding to the particular type of luminaire under study
UNE-EN 62493
Evaluation of lighting equipment in relation to human exposure to electromagnetic fields.
UNE-EN 61000-2-3
Electromagnetic compatibility (EMC). Part 3-2: Limits. Limits for harmonic current emissions (equipment with input current <= 16 A per phase).
UNE-EN 61000-3-3
Electromagnetic compatibility (EMC). Part 3-3: Limits. Limitation of voltage variations, voltage fluctuations and flicker in public low voltage supply networks for equipment with rated current <= 16 A per phase and not subject to conditional connection.
UNE-EN 55015
Limits and methods of measurement of the characteristics related to radioelectric disturbance of lighting equipment and similar.
UNE-EN 61547
Lighting equipment for general use. Requirements relating to EMC immunity.
UNE-EN 61347-2-13
Lamp control devices. Part 2-13: Particular requirements for electronic control devices powered with direct current or alternating current for LED modules.
UNE-EN 62471:2009
Photobiological safety of lamps and devices that use lamps.
UNE-EN 50581
Technical documentation for the evaluation of electrical and electronic products with regard to the restriction of hazardous substances
4.000 K
Neutral white light
3.000 K
Warm white light
2.700 K
Soft white light
XDL 2.200 K
Extra warm white light
PCA
Phosphor-Converted Amber
Protection degree IK10 - IP66 - IP44
Class
Certificates ENEC
Weight 7,5 kg
Color temperatures NDL 4.000 K, WDL 3.000 K, SDL 2.700 K, XDL 2.200 K, APC
Color rendering index >70
upper hemisphere flow <1% (zonas E1)
LED Duration (L90 B10 a Ta=25 ºC y Tj=95 ºC) 100.000 h
Photometric distribution (Optics) RG/ RJ/ RA/ RE/ RF/ RW